Sentron™ 5SY4113-6 Non Stock
printPrint
  1. pin-int

Sentron™ 5SY4113-6

5SY4113-6 Miniature Circuit Breaker, Sentron™, 230/400 VAC, 13 A, 5 kA Interrupt, 1 Poles, Thermal Magnetic Trip

  • MPN: 5SY4113-6
  • UPC: 754554875279
  • Min. Order Qty: 1
  • Quantity Interval: 1
  • loading loading
Sentron™ 5SY4113-6

Miniature circuit breakers are used to protect systems and installations in buildings and for industrial applications. Used in industrial applications and plant engineering, miniature circuit breakers can be supplemented with additional components, such as auxiliary switches, fault signal contacts, shunt trips, undervoltage releases, remote controlled mechanism, RC units, and arc fault detection devices. The devices are approved for worldwide use according to IEC standards for power supply systems up to 250/440 VAC. 72 VDC per pole is permitted in DC systems.

Sentron™ Miniature Circuit Breaker, Series: 5SY, 230/400 VAC, 13 A, 50/60 Hz Frequency, 5 kA Interrupt, Thermal/Magnetic Trip, 1.13 to 1.45 A Trip, 1 Pole, Handle Actuator, Screw Connection, 14 to 4 AWG Wire, IP20/IP40 Enclosure, DIN Rail Mounting, -25 to 55 deg C, 90 mm H x 18 mm W x 76 mm D Dimensions

Actuator Type      :      Handle
Connection Type      :      Screw
Dimensions      :      90 mm H x 18 mm W x 76 mm D
Enclosure Type      :      IP20/IP40
Frequency Rating      :      50/60 Hz
Mounting Type      :      DIN Rail
Series      :      5SY
Temperature Rating      :      -25 to 55 deg C
Trip Range      :      1.13 to 1.45 A
Wire Size      :      14 to 4 AWG
Voltage Rating      :      230/400 VAC
Amperage Rating      :      13 A
Interrupt Rating      :      5 kA
Number of Poles      :      1
Trip Type      :      Thermal/Magnetic
  • Clear and visible conductor connection in front of the rear busbar facilitates controls
  • The conductor is easily inserted into the terminal thanks to the large and easily accessible wiring space
  • Double terminal chambers permit accommodation of two wires of different cross-sections
  • Quick and easy manual removal of miniature circuit breakers from the busbar assembly, for example if connections need to be changed
  • Time-saving replacement of parts as busbars no longer need to be freed from adjacent devices
  • For the quick and easy mounting of auxiliary switches and fault signal contacts
  • Captive metal brackets on the additional components ensure the quick and easy mounting of devices on the miniature circuit breakers without the need for tools
  • Class B trip